Lacing
and Tying Cord
Gudebrod's
extensive textile experience and coating expertise has produced a wide range of custom
cords and cordage products. Working with materials such as Kevlar, Fiberglass,
Spectra, Nomex, Polyester, Nylon, Teflon, and Hair, we have engineered products ranging
from 0.006" through 0.125" diameter, with tensile strengths up to 250 Lbs.
Listed below are some that have become "standard"; other sizes and
constructions are certainly possible. Consult our Sales Department with your
requirements, and let us help solve your particular cordage problem.
Round Twisted Nylon Lacing Cord
Type
P (MIL T 713)
Temperature:
-67F to 250F (-55C to 121C)
Colors:
Natural (off-white) and Black
Put-up: 8
Ounce Spools Standard; Others available as special order.
Finish:
Fungicidal, Microcrystalline wax or Untreated.
Style 552
Braided Polyester Cord
Strength 4
to 250 Lbs. (Strength is determined by the size of the yarn used and the number of
yarns in the braid.)
Maximum
Temperature: 325F (163C)
Diameter:
0.006" to 0.125" (Diameter is determined by the size of the yarn used and the
number of yarns in the braid.)
Fiberglass Lacing and Tying Cord
(MIL Y 1140)
Description:
Twisted and cabled 100% fiberglass cord manufactured in accordance with MIL Y 1140.
Both Neoprene (N) coated and Uncoated (U) products are available.
Application:
Lacing, tying, banding, and wrapping used in the manufacture of electrical and
electronic apparatus. Excellent Flame resistance. The neoprene coating serves
to protect the fibers, bond the cord into a unified member, and improve handling and knot
retention properties.
Style 1875 - Self Extinguishing Polyester Tie Cord
(Meets
AT&T Specification 59122)
Description:
Twisted Polyester yarns saturated with a flame retardant finish to provide
self-extinguishing characteristics when subjected to open flame or elevated temperatures.
Application:
Lacing, tying, banding, and wrapping cord for use in bundling wire harness
assemblies where flammability is a concern.
Properties:
Complies with the requirements of Underwriter's Laboratories 94 V-0 rating.
Excellent knot retention. Self-extinguishes upon removal of flame source.
No emission of toxic by-products or halogens. Complies with AT&T
Specification 59122 for use in switchgear and cable harnessing applications.
Link To Our Site!
Dacron®, Kevlar®, Mylar®, Nomex®, and
Teflon® are registered trademarks of the Dupont Co.
Super G®, Champion®,
Monarch®, NCP®, HT®, Trimar®
and EZ-Dub® are registered trademarks of Gudebrod